Red.com RED ONE Provozní pokyny Strana 8

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 12
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 7
#
1
2
3
4
5
6
7
OPERATING MODE
BATTERY DETECTION
Bat1oncharge/Bat2waiting
BATTERY NOT ALLOWED
10Kohm < ID resistor < 60Kohm
BATTERY EVALUATION
i)Totalpackvoltage<8000mV
ii)I<10mA
If the charging does not rise within
30s, the battery does not accept
charge
iii)Individualcellvoltages<2800mV
10mA < I < 30mA
iv)Individualcellvoltages>2800mV
Total pack voltage < 13000mV
30mA < I < 300mA
CONSTANT CURRENT MODE
Stateofcharge:from0%to80%
13000mV < V < 16800, I = 4.8A
CONSTANT VOLTAGE MODE
Stateofcharge:from80%to100%
V =16800mV, 120mA < I < 4800mA
FULL CHARGE
V = 16800mV
I = 120mA
OTHER INDICATIONS
In the case of premature charge
termination, the charger retries to
charge after 30 seconds. If after 30
minutes, there is still no response, the
indication is changed into ‘BATTERY
FAILURE’ In the case of a battery
temporarily not accepting any charge
(i.e. an overheated battery) the
charger will retry every minute. In this
casethechargerashesredindicating
a temporary failure
TIME OUT
3600s
1200s
18000s
10800s
LED INDICATION
BATTERY WAITING:
GREEN:1sON/1sOFF
BATTERY NOT ALLOWED:
GREEN:500ms/RED:500ms
VOLTAGE TOO LOW:
RED:500msON/500msOFF
BATTERY FAILURE:
Steady RED
PRECHARGE-1:
ORANGE:500msON/500msOFF
PRECHARGE-2:
ORANGE:250msON/250msOFF
CC-MODE:
Steady ORANGE
CV-MODE:
80%to95%:ORANGE500ms/GREEN500ms
95%to100%:ORANGE1sec/GREEN1sec
FULL CHARGE:
Steady GREEN
PREMATURE CHARGE TERMINATION:
RED:250msON/100msOFF/250msON/
1sOFF(2blinks+1pause)
TEMPORARY FAILURE:
RED500msON/500msOFF
TECHNICAL SPECIFICATIONS:
Type Constant current and voltage
control system with timer interventions
CC-MODE:Outputcurrent 4800mA+/-2%
CC-MODE:Vmax 16800±50mV(0.3%)
CV-MODE:Vmax 16800±50mV(0.3%)
CV-MODE:Cutoffcurrent 120mA±10mA
Short circuit protection Available
Overcharge protection Available
Overtemperature protection Available
LEDS 3 colour type for BAT1, BAT2 and AUX
Special features IPCS and CTP
Auxiliarypower 13.8V100W(max)
Powersupply •ACmains100V~240V,
47~63Hzautoselect
Power consumption 220W
Operatingtemperaturerange 0°C-45°C
Storagetemperaturerange -20°C-65°C(-4°F-149°F)
Dimensions 250x145x80mm
Weight 970g
This charger has been tested for and is fully CE compliant.
06